Prerequisites REQUIRED

    Drive Connector SINAMICS

    Provided by SIEMENS

    Comprehensive integration of SINAMICS drive systems into Industrial Edge Platform for low and high-frequency data acquisition

    Drive Connector SINAMICS is an Industrial Edge application which supports easy connectivity with SINAMICS drives.

    Drive Connector SINAMICS provides four adapters:

    High-Speed-Adapter (HS Adapter) 

    • Supports CU320-2 based drives SINAMICS S120, S150, G130, G150 and SIMOTION D4X5-2(integrated CU320-2). 
    • Supports continuous data streaming up to 8kHz. Maximum speed depends on network and drive configuration
    • Requires the extension TRCDATA running on CU320-2
    Fingerprint-Adapter (Fingerprint)
    • Supports 2nd Generation SINAMICS S and G-type drives, V90-PN and SIMOTION D4X5-2(integrated CU320-2)
    • Supports Trace configuration (e.g. number of parameters, sampling cycle, Trace duration)
    • Generates time defined snapshot of the drive data
    • Fingerprint triggering via IE Databus enables the user to trigger fingerprint traces via the signals that are published on IE Databus by other IE applications ( e.g. external devices such as PLCs).
    • Fingerprint Adapter enables the user to receive traces that are configured via SINAMICS STARTER, Startdrive or V-Assistant by Fingerprint Adapter.
    Low-Speed-Adapter (LS Adapter)
    • Supports 2nd Generation SINAMICS S and G-type drives, V90-PN and  SIMOTION D4X5-2(integrated CU320-2) 
    • Supports continuous data streaming up to 10Hz
    UDP-Adapter
    • Supports SINAMICS G220 drives with IIoT Option Module(OM-IIoT)
    • Supports continuous data streaming up to 4kHz.
    • Requires IIoT Option Module(OM-IIoT) for each SINAMICS G220.
    Drive Status Information 
    • Drive Connector SINAMICS has a dedicated Drive Status Information page for each connected 2nd Gen SINAMICS drive.
    • Provides article, firmware and serial number for drive objects of each connected 2nd Gen SINAMICS drive. 
    • Provides basic drive status, faults and alarms and temperature data for existing drive objects of each connected  2nd Gen SINAMICS drive. 
    "Industrial Asset Hub " drive discovery and onboarding
    • Drive Connector SINAMICS enables "Industrial Asset Hub"(IAH) to scan, discover and onboard 2nd Gen SINAMICS drives on site. Article Number and FW version for each drive are provided  via Drive Connector SINAMICS to IAH and can be visualized in "Industrial Asset Hub". "Asset Gateway", IE application is required for IAH. 
    Automatic Discovery of 2nd Gen SINAMICS drives
    • Automatic discovery of 2nd Gen SINAMICS drives on site with network scan.
    Other features : 
    • Export and import single drive configuration or single adapter configuration for Low-Speed and Fingerprint-Adapter into a new drive or a new adapter.
    • Low-Speed-Adapter Simulator enables the user to simulate drive data(without a real drive) in the same format as LS adapter to be used in other IE applications such as Drivetrain Analyzer Edge.
    The web interface of Drive Connector SINAMICS supports configuration and starting the data acquisition process in a straightforward manner.
    By configuring Drive Connector SINAMICS, the target drive, drive object and signals can be selected easily.

    Entitlement
    A subscription for this Industrial Edge App entitles to:
    • create one (1) single instance of this Industrial Edge App on an Industrial Edge Device
    Volume Discounts: For bulk purchases and quantities over 100, you may please contact your Sales representative.

    Minimum Quantity Maximum Quantity Discount per Quantity Subscription Term
    0 To 24 Yearly
    25 To 49 5.00% Yearly
    50 To 99 10.00% Yearly
    100 To Max 10.00% Yearly

    The selected products cannot be added to cart. Please review and modify product selection.

    Total: USD $681.24 / year

    USD $56.77 / year after trial period

    You Save:

    Disclaimer: Taxes may apply
    You Save: 
    Billing Term: Yearly
    Subscription Term: Yearly
    You Purchased this Product before and cannot purchase it again
    You previously purchased a trial license of this product and cannot purchase again.
    Configuration should at least have one item, to add to cart
    Supported payment types: Credit Card/PayPal, Payment On Account

    Thank you for your interest in the MindSphere application Drive Connector SINAMICS . A member of the team will get in touch with you shortly about your request.

    Best regards,

    Your MindSphere team

    Your request has been timed out. Please try again.

    Added to cart

    Quantity

    Estimated total
    Tax calculated at checkout

    Key Features

    Drive Connector SINAMICS provides continuously connection between SINAMICS Drives and Edge Databus with below adapters.
    • High-Speed-Adapter supports continuous data acquisition up to 8kHz via Technology extension TRCDATA.
    • Fingerprint-Adapter generates time defined snapshot of the drive data and supports data acquisition up to 2 kHz.
    • Low-Speed-Adapter supports continuous data acquisition up to 10Hz.
    • Fingerprint Adapter enables the user to trigger fingerprint traces by the signals published on IE Databus. (e.g. external devices such as PLCs).
    • Fingerprint Adapter enables the user to receive traces that are configured via SINAMICS STARTER, Startdrive or V-Assistant by Fingerprint Adapter.
    • UDP-Adapter supports continuous data acquistion up to 4kHz for G220 with an IIoT Option Module(OM-IIoT)
    • Automatic discovery of 2nd Gen SINAMICS drives with network scan

    Benefits
    • Provides transparency about the status of the drive system at any time in high quality
    • Enables possibilities for basic, advanced analytics and maintenance scheduling like Mechanical Anomaly Detector, Operation Analyzer, IGBT Stress Analytics and Motor Current Signature Analysis in Drivetrain Analyzer Edge.
    • Enables possibilities for basic statistics like Energy Efficiency in Drivetrain Analyzer Edge.
    • Compare parameters and machine status at various points in time.
    • Opens doors for new innovative analysis approaches. 
    • Highly expandable with other Industrial Edge applications from the marketplace.
    • Easy update on app functionality through central Industrial Edge Management system.  
    • Collects drive data for defined machine operational state by fingerprint triggering via IE Databus functionality or trace configuration via STARTER, Startdrive or V-Assistant.